Noack volatility test

Test to determine evaporation loss of lubricants in high-temperature service

The Noack volatility test, named after Kurt Noack,[1] determines the evaporation loss of lubricants in high-temperature service. This test is standardized as ASTM D5800.[2]

In this test, a sample is heated at 250 °C for 60 minutes with a constant flow of air over it. The weight fraction lost is the result for the Noack volatility test.

As the lighter hydrocarbon fraction of motor oils evaporate, the viscosity of the remaining oil increases, contributing to poor circulation, reduced fuel economy, increased oil consumption, wear and tailpipe emissions.

References

  1. ^ K. Noack (1936). "Eine neue Laboratoriumsmethode zur Ermittlung der Verdampfbarkeit von Schmierölen für Verbrennungskraftmaschinen". Angew. Chem. 49 (25): 385–388. doi:10.1002/ange.19360492504.
  2. ^ "ASTM D5800-15a, Standard Test Method for Evaporation Loss of Lubricating Oils by the Noack Method". West Conshohocken, PA: ASTM International. 2015. doi:10.1520/D5800-15A. {{cite journal}}: Cite journal requires |journal= (help)